Ansi Mc 96.1 Standard
International Thermocouple And Extension wire COLOR CODES
- Ansi Mc 96.1 Standard Dimensions
- Ansi Mc96.1 Standard Size
- What Is Ansi Mc96.1
- Ansi Mc96.1 Standard Wire
ANSI MC96 1 PDF. ANSI MC Temperature Measurement Thermocouples Establishes uniformity in the designation of thermocouples and extension wires and provides,. ISA–MC–, Temperature Measurement Thermocouples. Constitute an endorsement of the thermocouple type by ISA, ANSI, and NBS. ANSI/KCMA A161.1 Standard In accordance with the procedures set by ANSI for the revision of standards, KCMA has initiated the canvass balloting process for the KCMA A161.1 standard. KCMA has also sent a request to ANSI to publish a notice in Standards Action that the KCMA A161.1 standard is under review and KCMA is soliciting public comment on.
Ansi Mc 96.1 Standard Dimensions
Country | USA | United Kingdom | Germany | Japan | France | |
---|---|---|---|---|---|---|
National Standard | ANSI MC 96.1 T/C | ANSI MC 96.1 Extension | BS 1843 | DIN 43714 | JIS C1610-1981 | NF C42-323 |
Overall (J) | Brown | Black | Black | Blue | Yellow | Black |
Positive | White | White | Yellow | Red | Red | Yellow |
Negative | Red | Red | Blue | Blue | White | Black |
Overall (K) | Brown | Yellow | Red | Green | Blue | Yellow |
Positive | Yellow | Yellow | Brown | Red | Red | Yellow |
Negative | Red | Red | Blue | Green | White | Purple |
Overall (E) | Brown | Purple | Brown | Black | Purple | — |
Positive | Purple | Purple | Brown | Red | Red | — |
Negative | Red | Red | Blue | Black | White | — |
Overall (T) | Brown | Blue | Blue | Brown | Brown | Blue |
Positive | Blue | Blue | White | Red | Red | Yellow |
Negative | Red | Red | Blue | Brown | White | Blue |
Overall (R) | — | Green | Green | — | Black | — |
Positive | — | Black | White | — | Red | — |
Negative | — | Red | Blue | — | White | — |
Overall (S) | — | Green | Green | White | Black | Green |
Positive | — | Black | White | Red | Red | Yellow |
Negative | — | Red | Blue | White | White | Green |
Overall (B) | — | Grey | — | Grey | Grey | — |
Positive | — | Grey | — | Red | Red | — |
Negative | — | Red | — | Grey | White | — |
Overall (N) | Brown | Orange | — | — | — | — |
Positive | Orange | Orange | — | — | — | — |
Negative | Red | Red | — | — | — | — |
Ansi Mc96.1 Standard Size
Search Our Site
Other Thermocouple Wires
ANSI | American National Standard Institute |
ANSI MC 96.1 | Temperature measurement thermocouples |
BS | British Standard Institution |
BS 4937l | International thermocouple reference tables |
BS 5308 | Standard for instrumentation cables |
BS 5839-1 | Fire detection and alarm system for building. Code of practice |
BS 6387 | Specification for performance requirements for cables required to maintain circuit integrity under fire conditions |
BS 6425-1 | Method of determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables |
BS 6425-2 | Determination of degree of acidity (corrosivity) of gases by measuring PH and conductivity |
BS 6724, Appendix F | Measurement of smoke density using the 3 m test cube (Absorbance) |
BS 7622 | Measurement of smoke density of electric cables burning under defined conditions (LT) |
BS 8434 | Method of test for assessment of the fire integrity of electric cables |
CEI | Comitato Elettrotecnico ItalianoCEI |
CEI 20-11 EN 50363 | Insulating, sheathing and covering materials for low voltage energy cables |
CEI 20-22/2 | Prove di incendio su cavi elettrici. Prova di non propagazione dell’incendio |
CEI 20-22/3 EN 50266 | Test for vertical flame spread of vertically-mounted bunched wires and cables |
CEI 20-29 EN 60228 | Conductors of insulated cables |
CEI 20-35/1 EN 60332-1 | Test for vertical flame propagation for a single insulated wire or cable |
CEI 20-36/1 CEI 20-36/2 IEC 60331 | Test for electrical cables under fire conditions. Circuit integrity |
CEI 20-37/2-1 EN 50267-2-1 | Method of determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables |
CEI 20-37/2-2 EN 50267-2-2 | Determination of degree of acidity (corrosivity) of gases by measuring PH and conductivity |
CEI 20-37/2-3 EN 50267-2-3 | Determination of degree of acidity of gases for cables by determination of weighted average of pH and conductivity |
CEI 20-37/3 EN 61034 | Measurement of smoke density of cables burning under defined conditions |
CEI 20-37/4 | Determinazione dell’indice di tossicità dei gas emessi dai cavi |
CEI 20-37/6 | Misura della densità del fumo emesso da materiali dei cavi sottoposti a combustione in condizioni definite. Metodo dei 300 grammi |
CEI 46-143 EN 50288-7 | Sectional specification for instrumentation and control cables |
CEI 65-20 | Termocoppie - Parte 3: Tolleranze e metodo di identificazione dei cavi di estensione e di compensazione |
DIN | Deutsches Institut fur NormungDIN |
DIN 43710 | Thermospanungen und werkstoffe der thermopaare |
DIN 47100 | Fernmeldeschnuere; Kennzeichnung der Adern, Farben der Aussenhuellen |
DIN 60584 | Thermocouples |
EEMA | Engineering Equipment and Material Users Ass. |
EEMUA 133 | Specification for underground armoured cable protected against solvent penetration and corrosive attack |
EN | European Norm |
EN 50200 | Methods of test for resistance to fire of unprotected small cables for use in emergency circuit |
EN 50266 | Test for vertical flame spread of vertically-mounted bunched wires and cables |
EN 50267/2-1 | Method of determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables |
EN 50267/2-2 | Determination of degree of acidity (corrosivity) of gases by measuring PH and conductivity |
EN 50288-7 | Sectional specification for instrumentation and control cables |
EN 50362 | Method of test for resistance to fire of larger unprotected power and control cables for use in emergency circuits |
EN 50363 | Insulating, sheathing and covering materials for low voltage energy cables |
EN 60228 | Conductors of insulated cables |
EN 60332-1 | Test for vertical flame propagation for a single insulated wire or cable |
EN 60332-2 | Test for vertical flame propagation for a single small insulated wire or cable |
EN 61034 | Measurement of smoke density of cables burning under defined conditions |
ICEA NEMA | Insulated Cables Engineers Association National Electrical Manufacturers Association |
ICEA S-73-532 NEMA WC 57 | Standard for Control, Thermocouple Extension, and Instrumentation Cables |
IEC | International Electrotechnical Commission |
IEC 60092-3 | Cables: construction, testing and installation |
IEC 60228 | Conductors of insulated cables - Guide to the dimensional limits of circular connectors |
IEC 60331 | Test for electrical cables under fire conditions. Circuit integrity. Part 21 - Cables of rated voltage up to and including 0.6/ 1.0 kV Part 23 - Electric data cables Part 25 - Optical fibre cables |
IEC 60332-1 | Test on electric cables under fire conditions. Test on a single vertical insulated wire or cable |
IEC 60332-2 | Test on electric cables under fire conditions. Test on a single small vertical insulated copper wire or cable |
IEC 60332-3 | Test on electric cables under fire conditions.Test for vertical flame spread of vertically-mounted bunched wires or cables |
IEC 60502 | Power cables with extruded insulation and their accessories for rated voltages from 1 kV (Um = 1,2 kV) up to 30 kV (Um = 36 kV) |
IEC 60754-1 | Method for determination of amount of halogen acid gas evolved during combustion of polymeric materials taken from cables |
IEC 60754-2 | Determination of degree of acidity (corrosivity) of gases by measuring pH and conducivity |
IEC 60584 | Extension and compensating cables |
IEC 61034-2 | Measurement of smoke density of electric cables burning under defined conditions (LT) |
IEEE | Institute of Electrical and Electronics Engineering |
IEEE 383 | Standard for Type Test of Class 1E Electric Cables, Field Splices and Connections for Nuclear Power Generating Stations |
NEK | Norsk Elektroteknisk Komite |
NEK 606 | Cables for offshore installations halogen-free and/or mud resistant |
NF | Norme Française |
NF-C-32-070 | Essais de clasification des conducteurs et cables du point de vue de leur comportament au feu |
NF-C-42-324 | Cables d'extention et de compensation pour couples thermoelectriques.Composition, nature des materiaux, essais de fabrication |
NF-X-70-100 | Analyse de gaz de pyrolyse et de combustion |
NF M 87-201 | Câbles d'extension ed de compensation pour thermocouples |
NF M 87-202 | Industrie du pétrole - Câbles d'instrumentation |
UNI | Ente Nazionale Italiano di Unificazione |
UNI 7938 | Termocoppie - Classificazione e caratteristiche statiche |
UTE | Union Tecnique de l’Electricitè |
UTE C 20 -454 | Methode d’essai pour l’analyse et la dosage de gaz nocifs |